Annex C — Textiles & Apparel

Sector annex to Morocco UNS Standard v0.1. Covers Moroccan textile and apparel production: spinning, weaving/knitting, dyeing/finishing, cut-make-trim (CMT), and laundry. Strategic anchor: Morocco’s textile/apparel exports (largely to EU, fast-fashion-driven) make energy, water, and chemical-batch transparency commercially valuable beyond compliance — brand audits (ZDHC, Higg FEM, BSCI) consume the same signals.


C.1 Scope

Covers vertically integrated mills and CMT operations. Excludes raw-cotton agriculture and end-retail logistics.


C.2 Enterprise & Site archetypes

Moroccan textile is fragmented: hundreds of SMEs, a handful of mid-cap groups, and supplier networks for European brands (Inditex, H&M, Decathlon). There is no equivalent of OCP. Use the legal-entity slug; if the producer operates under multiple brands, use the operating company.

C.2.1 Cluster regions

RegionCluster
ma-06 Casablanca-SettatCasablanca, Berrechid, Mohammedia
ma-01 Tanger-TétouanTangier, Tétouan
ma-03 Fès-MeknèsFès, Meknès
ma-04 Rabat-Salé-KénitraSalé, Kénitra

C.2.2 Site naming

Use city + plant tag: casablanca-plant-1, tangier-cmt-2, fes-mill.


C.3 Area inventory

Area segmentDescription
spinningYarn production (rare in Morocco; mostly imported yarn)
weavingLoom hall
knittingCircular and flat knitting
dyeingJet, jigger, beam, package dyeing
printingRotary, digital print
finishingStenter, calender, sanforizing
washingIndustrial washing (denim, garment wash)
cmtCut-make-trim sewing lines
pressingFinal pressing, packing
etpEffluent treatment plant
boiler-houseSteam generation
compressed-airUtility

C.4 Equipment archetypes

Equipment segmentExamplesCommon signals
loom-<n>loom-air-jet-12rpm, picks-count, efficiency-pct, state
knit-machine-<n>knit-circular-04rpm, course-count, state
jet-dyeing-<n>jet-dyeing-jd03bath-temperature-c, bath-volume-m3, ph, chemical-dose-kg, state
stenter-<n>stenter-st02zone-temperature-c, fabric-speed-mmin, fuel-flow-m3h, energy-kwh
washing-machine-<n>washing-w08water-flow-m3h, bath-temperature-c, energy-kwh
boiler-<n>boiler-b01steam-flow-tph, fuel-flow-m3h, co2-flow-kgh
compressor-<n>compressor-c01discharge-pressure-bar, energy-kwh
etp-aerator-<n>etp-aerator-04dissolved-oxygen-mgl, energy-kwh
cmt-line-<n>cmt-line-12pieces-count, defect-count, oee-pct

C.5 Mandatory signals — energy + water + chemicals

Textiles is unique among the Moroccan sectors covered by this standard in having water and chemicals as first-class signals alongside energy.

Per Site, the following utility totals MUST be published (at a virtual utilities/site-summary if no PLC owns them):

  • electricity-kwh — total grid + on-site generation
  • gas-m3 — natural gas consumption (boiler house)
  • water-intake-m3 — total
  • water-discharge-m3 — total to ETP
  • etp-cod-mgl — chemical oxygen demand of effluent
  • etp-bod-mgl — biological oxygen demand
  • chemical-consumption-kg — by chemical class (pigment, auxiliary, surfactant)

ZDHC alignment

The ZDHC (Zero Discharge of Hazardous Chemicals) Wastewater Guidelines are the de facto audit standard. Fields for etp-* signals MUST use the ZDHC parameter list verbatim where one exists; this lets a brand audit consumer re-use the UNS data without translation.


C.6 CBAM exposure

Textiles is not currently in CBAM scope (as of v0.1). The standard nonetheless flags boiler-house and stenter energy/fuel signals as cbam_relevant: true because:

  • The EU is widely expected to extend CBAM to textiles by 2030
  • The same signals feed CSRD Scope 1/2 today

This is conservative; downgrade to false only if explicitly directed by the brand customer.


C.7 Worked path examples

ma/ma-06/groupe-x/casablanca-plant-1/dyeing/jet-dyeing-jd03/bath-temperature-c
ma/ma-06/groupe-x/casablanca-plant-1/finishing/stenter-st02/fuel-flow-m3h
ma/ma-01/cmt-y/tangier-cmt-2/cmt/cmt-line-12/oee-pct
ma/ma-06/groupe-x/casablanca-plant-1/etp/site-summary/etp-cod-mgl
ma/ma-06/groupe-x/casablanca-plant-1/utilities/site-summary/water-intake-m3

C.8 Strategic notes

  • Textile SMEs are the canonical DigiTPME target; this annex is also the most relevant for Digital Morocco 2030 SME diagnostics.
  • A small UNS deployment (single broker, ~50 signals) is feasible at SME scale and produces immediate value for energy and ZDHC reporting.
  • Brand audits (ZDHC InCheck, Higg FEM verification) require the same signals — adoption is double-counted against compliance and customer-facing reporting.